Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ann Med ; 54(1): 3189-3200, 2022 12.
Artículo en Inglés | MEDLINE | ID: covidwho-2106905

RESUMEN

INTRODUCTION: In order to identify therapeutic targets in Coronavirus disease 2019 (COVID-19), it is important to identify molecules involved in the biological responses that are modulated in COVID-19. Lysophosphatidic acids (LPAs) are involved in the pulmonary inflammation and fibrosis are one of the candidate molecules. The aim of this study was to evaluate the association between the serum levels of autotaxin (ATX), which are enzymes involved in the synthesis of lysophosphatidic acids. MATERIAL AND METHODS: We enrolled 134 subjects with COVID-19 and 58 normal healthy subjects for the study. We measured serum ATX levels longitudinally in COVID-19 patients and investigated the time course and the association with severity and clinical parameters. RESULTS: The serum ATX levels were reduced in all patients with COVID-19, irrespective of the disease severity, and were negatively associated with the serum CRP, D-dimer, and anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody levels. DISCUSSION: Considering the biological properties of LPAs in the pulmonary inflammation and fibrosis, modulation of ATX might be compensatory biological responses to suppress immunological overreaction especially in the lung, which is an important underlying mechanism for the mortality of the disease. CONCLUSIONS: COVID-19 patients showed a decrease in the serum levels of ATX, irrespective of the disease severity. Key MessagesAutotaxin (ATX) is an enzyme involved in the synthesis of lysophosphatidic acid (LPA), which has been reported to be involved in pulmonary inflammation and fibrosis. Patients with COVID-19 show decrease in the serum levels of ATX. Modulation of ATX might be compensatory biological responses to suppress immunological overreaction.


Asunto(s)
COVID-19 , Hidrolasas Diéster Fosfóricas , Humanos , COVID-19/sangre , Fibrosis , Pulmón , Lisofosfolípidos , Hidrolasas Diéster Fosfóricas/sangre , SARS-CoV-2
2.
Int Immunopharmacol ; 103: 108491, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: covidwho-1587489

RESUMEN

To better understand the immune responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in individuals with COVID-19, it is important to investigate the kinetics of the antibody responses and their associations with the clinical course in different populations, since there seem to be considerable differences between Western and Asian populations in the clinical features and spread of COVID-19. In this study, we serially measured the serum titers of IgM, IgG and IgA antibodies generated against the nucleocapsid protein (NCP), S1 subunit of the spike protein (S1), and receptor-binding domain in the S1 subunit (RBD) of SARS-CoV-2 in Japanese individuals with COVID-19. Among the IgM, IgG, and IgA antibodies, IgA antibodies against all of the aforementioned viral proteins were the first to appear after the infection, and IgG and/or IgA seroconversion often preceded IgM seroconversion. In regard to the timeline of the antibody responses to the different viral proteins (NCP, S1 and RBD), IgA against NCP appeared than IgA against S1 or RBD, while IgM and IgG against S1 appeared earlier than IgM/IgG against NCP or RBD. The IgG responses to all three viral proteins and responses of all three antibody classes to S1 and RBD were sustained for longer durations than the IgA/IgM responses to all three viral proteins and responses of all three antibody classes to NCP, respectively. The seroconversion of IgA against NCP occurred later and less frequently in patients with mild COVID-19. These results suggest possible differences in the antibody responses to SARS-CoV-2 antigens between the Japanese and Western populations.


Asunto(s)
COVID-19/epidemiología , COVID-19/inmunología , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2 , Formación de Anticuerpos , Pueblo Asiatico , Humanos , Inmunoglobulina A/inmunología , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Japón/epidemiología , Japón/etnología , Seroconversión , Proteínas Virales/inmunología
4.
J Infect Chemother ; 27(9): 1342-1349, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: covidwho-1267751

RESUMEN

INTRODUCTION: The worldwide pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has continued to date. Given that some of the patients with coronavirus disease 2019 (COVID-19) are asymptomatic, antibody tests are useful to determine whether there is a previous infection with SARS-CoV-2. In this study, we measured IgM and IgG antibody titers against SARS-CoV-2 in the serum of asymptomatic healthy subjects in The University of Tokyo, Japan. METHODS: From June 2020, we recruited participants, who were students, staff, and faculty members of The University of Tokyo in the project named The University of Tokyo COVID-19 Antibody Titer Survey (UT-CATS). Following blood sample collection, participants were required to answer an online questionnaire about their social and health information. We measured IgG and IgM titers against SARS-CoV-2 using iFlash-SARS-CoV-2 IgM and IgG detection kit which applies a chemiluminescent immunoassay (CLIA) for the qualitative detection. RESULTS: There were 6609 volunteers in this study. After setting the cutoff value at 10 AU/mL, 32 (0.48%) were positive for IgG and 16 (0.24%) for IgM. Of six participants with a history of COVID-19, five were positive for IgG, whereas all were negative for IgM. The median titer of IgG was 0.40 AU/mL and 0.39 AU/mL for IgM. Both IgG and IgM titers were affected by gender, age, smoking status, and comorbidities. CONCLUSIONS: Positive rates of IgG and IgM titers were relatively low in our university. Serum levels of these antibodies were affected by several factors, which might affect the clinical course of COVID-19.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Estudios Epidemiológicos , Humanos , Inmunoglobulina G , Inmunoglobulina M , Japón/epidemiología
5.
Sci Rep ; 11(1): 5190, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: covidwho-1117666

RESUMEN

In Coronavirus disease 2019 (COVID-19) subjects, recent evidence suggests the presence of unique coagulation abnormalities. In this study, we performed clot waveform analyses to investigate whether specific modulations are observed in COVID-19 subjects. We analyzed the second derivative of the absorbance in routine APTT tests performed using an ACL-TOP system. We observed high frequencies of abnormal patterns in APTT second-derivative curves that could be classified into an early shoulder type, a late shoulder type, or a biphasic type, high maximum first-derivative and second-derivative peak levels, and a low minimum second-derivative peak level in COVID-19 subjects. These modulations were not observed in subjects with disseminated intravascular coagulation. These abnormal patterns are also observed in patients with lupus anticoagulant, hemophilia, or factor IX deficiency. The plasma fibrinogen levels might also be involved in the abnormal APTT waveforms, especially the high maximum first-derivative and second-derivative peak levels. The abnormal patterns in the APTT second-derivative curves appear with highest frequency at around 2 weeks after the onset of COVID-19 and were not associated with the severity of COVID-19. These results suggest the possible presence of a specific abnormal coagulopathy in COVID-19.


Asunto(s)
Coagulación Sanguínea , COVID-19/sangre , Anciano , Pruebas de Coagulación Sanguínea , Femenino , Fibrinógeno/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos , Triazoles
6.
PLoS One ; 16(3): e0247711, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1117485

RESUMEN

PCR methods are presently the standard for the diagnosis of Coronavirus disease 2019 (COVID-19), but additional methodologies are needed to complement PCR methods, which have some limitations. Here, we validated and investigated the usefulness of measuring serum antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the iFlash3000 CLIA analyzer. We measured IgM and IgG titers against SARS-CoV-2 in sera collected from 26 PCR-positive COVID-19 patients, 53 COVID-19-suspected but PCR-negative patients, and 20 and 100 randomly selected non-COVID-19 patients who visited our hospital in 2020 and 2017, respectively. The repeatability and within-laboratory precision were obviously good in validations, following to the CLSI document EP15-A3. Linearity was also considered good between 0.6 AU/mL and 112.7 AU/mL for SARS-CoV-2 IgM and between 3.2 AU/mL and 55.3 AU/mL for SARS-CoV-2 IgG, while the linearity curves plateaued above the upper measurement range. We also confirmed that the seroconversion and no-antibody titers were over the cutoff values in all 100 serum samples collected in 2017. These results indicate that this measurement system successfully detects SARS-CoV-2 IgM/IgG. We observed four false-positive cases in the IgM assay and no false-positive cases in the IgG assay when 111 serum samples known to contain autoantibodies were evaluated. The concordance rates of the antibody test with the PCR test were 98.1% for SARS-CoV-2 IgM and 100% for IgG among PCR-negative cases and 30.8% for SARS-CoV-2 IgM and 73.1% for SARS-CoV-2 IgG among PCR-positive cases. In conclusion, the performance of this new automated method for detecting antibody against both N and S proteins of SARS-CoV-2 is sufficient for use in laboratory testing.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2/aislamiento & purificación , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/epidemiología , COVID-19/inmunología , Proteínas de la Nucleocápside de Coronavirus/inmunología , Proteínas de la Nucleocápside de Coronavirus/aislamiento & purificación , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Japón/epidemiología , Mediciones Luminiscentes/métodos , Fosfoproteínas/inmunología , Fosfoproteínas/aislamiento & purificación , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/aislamiento & purificación
7.
Sci Rep ; 11(1): 2776, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: covidwho-1061095

RESUMEN

The accurate and prompt diagnosis of SARS-CoV-2 infection is required for the control and treatment of the coronavirus infection disease 2019 (COVID-19). In this study, we aimed to investigate the time courses of the anti-severe acute corona respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM and IgG titers and to evaluate the sensitivity and specificity of such tests according to the specific day after the onset of COVID-19 among a patient population in Japan. We measured the titers of SARS-CoV-2 IgM and IgG in sera from 105 subjects, including 26 symptomatic COVID-19 patients, using chemiluminescent immunoassay (CLIA) methods utilizing magnetic beads coated with SARS-CoV-2 nucleocapsid protein and spike protein. The results of a ROC analysis suggested the possibility that the cutoff values in Japan might be lower than the manufacturer's reported cutoff (10 AU/mL): 1  AU/mL for IgM and 5  AU/mL for IgG. The sensitivity of the test before Day 8 after symptom onset was less than 50%; at Days 9-10, however, we obtained a much higher sensitivity of 81.8% for both IgM and IgG. At 15 days or later after symptom onset, the SARS-CoV-2 IgG test had a sensitivity of 100%. These results suggest that if the number of days since disease onset is taken into consideration, these antibody tests could be very useful for the diagnosis of COVID-19 and similar diseases.


Asunto(s)
Especificidad de Anticuerpos , COVID-19/inmunología , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , SARS-CoV-2/inmunología , COVID-19/virología , Prueba de COVID-19 , Ensayo de Inmunoadsorción Enzimática , Humanos , Japón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA